Performing Terminal UltraLight Service Procedures

This page describes the service procedures available for Terminal UltraLight and Network Card Reader. For a better understanding, we use the word terminal on this page, which refers to Terminal UltraLight, and also Network Card Reader.

Downloading the Firmware Files and Update Firmware

  1. Download the new firmware files from the Konica Minolta Partner Portal (http://partners.ysoft.com) to Dispatcher Paragon Server.

  2. Copy the new firmware files into the "update" folder (typically: C:/SafeQ/server/update).

  3. Start termtool.exe application.

  4. Use update firmware procedure described in Remote configuration tool for hardware terminals - Update Standard Firmware of YSoft SafeQ Terminal UltraLight

  5. Try to authenticate on the terminal.

    If you are able to authenticate, you have successfully performed one of the selected procedures.

Default Configuration Settings

Default configuration settings for Network Card Reader:

  • DHCP: Disabled

  • IP:192.168.0.100

  • Netmask: 255.255.255.0

  • Gateway: 192.168.0.254

  • DNS: 192.168.0.254

  • Primary server: 192.168.0.254:5011

  • Server list: empty

  • Update server: 192.168.0.254:4096

  • Sound: Enabled

Default configuration settings for Terminal UltraLight:

  • DHCP: Disabled

  • IP:192.168.0.100

  • Netmask: 255.255.255.0

  • Gateway: 192.168.0.254

  • DNS: 192.168.0.254

  • Primary server: 192.168.0.254:4096

  • Server list: empty

  • Locking: Immediate

  • Auth. type: Card or PIN

  • Mode: Normal

  • Sound: Enabled

  • Debug mode: No log

  • IOmodue mode: 0

Terminal UltraLight and Network card reader are shipped with the configuration reset to default.